← All methods

Turbocompressor K-250

A large turbocompressor station. The effect is measured not by pressure but by electricity: how many kilowatt-hours are spent per thousand cubic meters of air.

K-250 air turbocompressor station, 1800 l oil system, up to 10 000 rpm

The class norm is 0.8 ml per liter. For this machine there are two revisions of the applied procedure: 1.2 ml/l in 3 stages and 0.9 ml/l in 4 stages. The total is the same in both — 6480 ml; which one to apply is decided by the XADO engineer. Screw and centrifugal compressors →

What is treated

What is measured before and after

ParameterInstrumentHow and when
Electricity consumption over a fixed intervalelectricity meterFor example, over 20 minutes recalculated to an hour; separately — at idle running.
Specific electricity consumption per 1000 m³ of aircalculation from the meterMeasurements are comparable only at the same temperature of the air being pumped: a difference of 5–10 °C has a noticeable effect.
Vibration level of each bearing supportvibrometerVibration displacement, vibration velocity, vibration acceleration in the horizontal, vertical and axial directions.
Operating temperature of the plain bearingsthermometerAt the same cooling intensity.
Tooth thickness of the step-up gearboxgear tooth vernier caliperOver the constant chord, with a description of the contact patterns.

Dosage rates

CompoundRateHow and when
Gel for compressors and bearings — 3-stage revision1.2 ml per 1 liter of standard oil per stage1800 l system: 2160 ml per stage, 6480 ml in total. The interval between stages is not earlier than 8 and not later than 16 hours.
The same gel — 4-stage revision0.9 ml per 1 liter of standard oil per stage1620 ml per stage, 6480 ml in total. The second stage after 24 hours, the third and fourth — after 12 hours.

Treatment stages

  1. Dilute the gel in 4–7 l of standard oil heated to 50–60 °C, stir until completely dissolved and add to the oil system of the station.Start of the total operating time count
  2. The second stage — the same as the first.After 8–16 hours of total operating time
  3. The third stage — the same as the first.After another 8–16 hours of operating time

After treatment

Points to watch

Where К-250 has already been treated

  1. Rosava JV JSC · 2004↓ 5.3% — power consumed by the motor at no load, 743.04 → 703.4 kW

Source: XADO applied procedure, lead engineer I. N. Sharaikin. Class norm — instruction IE-24.6-25612000-005-2008, procedure No. 2. Analysis: state/DRIVE_METHODS.md.